REG_MATES_DIOX_MK1_ODEF_TYPE Union Reference

Data Fields

struct {
   UINT32T   ODEF_O01: 1
 
   UINT32T   ODEF_O02: 1
 
   UINT32T   ODEF_O03: 1
 
   UINT32T   ODEF_O04: 1
 
   UINT32T   ODEF_O05: 1
 
   UINT32T   ODEF_O06: 1
 
   UINT32T   ODEF_O07: 1
 
   UINT32T   ODEF_O08: 1
 
   UINT32T   ODEF_O09: 1
 
   UINT32T   ODEF_O10: 1
 
   UINT32T   ODEF_O11: 1
 
   UINT32T   ODEF_O12: 1
 
   UINT32T   ODEF_O13: 1
 
   UINT32T   ODEF_O14: 1
 
   UINT32T   ODEF_O15: 1
 
   UINT32T   ODEF_O16: 1
 
   UINT32T   ODEF_O17: 1
 
   UINT32T   ODEF_O18: 1
 
   UINT32T   ODEF_O19: 1
 
   UINT32T   ODEF_O20: 1
 
   UINT32T   ODEF_RSRVD: 10
 
   UINT32T   ODEF_VXS: 2
 
fields
 
UINT32T all
 

Detailed Description

Outputs default value register. type (MATES_DIOX_MK1).

Field Documentation

UINT32T ODEF_O01

OUT01 default value after startup.

UINT32T ODEF_O02

OUT02 default value after startup.

UINT32T ODEF_O03

OUT03 default value after startup.

UINT32T ODEF_O04

OUT04 default value after startup.

UINT32T ODEF_O05

OUT05 default value after startup.

UINT32T ODEF_O06

OUT06 default value after startup.

UINT32T ODEF_O07

OUT07 default value after startup.

UINT32T ODEF_O08

OUT08 default value after startup.

UINT32T ODEF_O09

OUT09 default value after startup.

UINT32T ODEF_O10

OUT10 default value after startup.

UINT32T ODEF_O11

OUT11 default value after startup.

UINT32T ODEF_O12

OUT12 default value after startup.

UINT32T ODEF_O13

OUT13 default value after startup.

UINT32T ODEF_O14

OUT14 default value after startup.

UINT32T ODEF_O15

OUT15 default value after startup.

UINT32T ODEF_O16

OUT16 default value after startup.

UINT32T ODEF_O17

OUT17 default value after startup.

UINT32T ODEF_O18

OUT18 default value after startup.

UINT32T ODEF_O19

OUT19 default value after startup.

UINT32T ODEF_O20

OUT20 default value after startup.

UINT32T ODEF_RSRVD

Reserved, do not use.

UINT32T ODEF_VXS

$V_{X}$ voltage selection:

  • 00b - $V_{X}$ comes from the external voltage connector 5-30 VDC
  • 10b - $V_{X}$ comes from the system PSU (24 V)
  • 11b (default) - $V_{X}$ comes from the internal 5 V voltage regulator
  • 01b - invalid

{The 11b setting cannot be applied (changed to) when external voltage is present at the 5-30 VDC connector. This is done to protect internal electronics from a voltage spike during switching. To be able to set VXS to this value, turn off or disconnect the external voltage.}\ {Changing VXS may take over two seconds.}

struct { ... } fields

Particular fields.

UINT32T all

All bits.


The documentation for this union was generated from the following file: