Outputs default value register. type (MATES_DIOX_MK1).
More...
|
UInt32 | VXS [get, set] |
| $V_{X}$ voltage selection: More...
|
|
UInt32 | RSRVD [get, set] |
| Reserved, do not use. More...
|
|
UInt32 | O20 [get, set] |
| OUT20 default value after startup. More...
|
|
UInt32 | O19 [get, set] |
| OUT19 default value after startup. More...
|
|
UInt32 | O18 [get, set] |
| OUT18 default value after startup. More...
|
|
UInt32 | O17 [get, set] |
| OUT17 default value after startup. More...
|
|
UInt32 | O16 [get, set] |
| OUT16 default value after startup. More...
|
|
UInt32 | O15 [get, set] |
| OUT15 default value after startup. More...
|
|
UInt32 | O14 [get, set] |
| OUT14 default value after startup. More...
|
|
UInt32 | O13 [get, set] |
| OUT13 default value after startup. More...
|
|
UInt32 | O12 [get, set] |
| OUT12 default value after startup. More...
|
|
UInt32 | O11 [get, set] |
| OUT11 default value after startup. More...
|
|
UInt32 | O10 [get, set] |
| OUT10 default value after startup. More...
|
|
UInt32 | O09 [get, set] |
| OUT09 default value after startup. More...
|
|
UInt32 | O08 [get, set] |
| OUT08 default value after startup. More...
|
|
UInt32 | O07 [get, set] |
| OUT07 default value after startup. More...
|
|
UInt32 | O06 [get, set] |
| OUT06 default value after startup. More...
|
|
UInt32 | O05 [get, set] |
| OUT05 default value after startup. More...
|
|
UInt32 | O04 [get, set] |
| OUT04 default value after startup. More...
|
|
UInt32 | O03 [get, set] |
| OUT03 default value after startup. More...
|
|
UInt32 | O02 [get, set] |
| OUT02 default value after startup. More...
|
|
UInt32 | O01 [get, set] |
| OUT01 default value after startup. More...
|
|
Outputs default value register. type (MATES_DIOX_MK1).
$V_{X}$ voltage selection:
-
00b - $V_{X}$ comes from the external voltage connector 5-30 VDC
-
10b - $V_{X}$ comes from the system PSU (24 V)
-
11b (default) - $V_{X}$ comes from the internal 5 V voltage regulator
-
01b - invalid
{The 11b setting cannot be applied (changed to) when external voltage is present at the 5-30 VDC connector. This is done to protect internal electronics from a voltage spike during switching. To be able to set VXS to this value, turn off or disconnect the external voltage.}\ {Changing VXS may take over two seconds.}
OUT20
default value after startup.
OUT19
default value after startup.
OUT18
default value after startup.
OUT17
default value after startup.
OUT16
default value after startup.
OUT15
default value after startup.
OUT14
default value after startup.
OUT13
default value after startup.
OUT12
default value after startup.
OUT11
default value after startup.
OUT10
default value after startup.
OUT09
default value after startup.
OUT08
default value after startup.
OUT07
default value after startup.
OUT06
default value after startup.
OUT05
default value after startup.
OUT04
default value after startup.
OUT03
default value after startup.
OUT02
default value after startup.
OUT01
default value after startup.
PropertyChangedEventHandler PropertyChanged |
|
inherited |
Raised when a property on this object has a new value.
The documentation for this class was generated from the following file: